CVE-2022-22805

Schneider Electric SmartConnect: buffer overflow / out-of-bounds writeTítulo compuesto por nday; el registro CVE no tiene título.

Schneider Electric / SmartConnect

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

buffer overflow / out-of-bounds write
CWE-120, stated by the CNA schneider, NVD's analysts y NVD, republishing [email protected]
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
network
AV:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
no authentication required
PR:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
no user interaction
UI:N in CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.1) from NVD's analysts
ICS / OT
affected products in the CVE record: Schneider Electric · SmartConnectCPE names NVD's analysts give as vulnerable: o:schneider-electric:scl_series_1029_ups_firmware, o:schneider-electric:scl_series_1030_ups_firmware, o:schneider-electric:scl_series_1036_ups_firmware, o:schneider-electric:scl_series_1037_ups_firmware, o:schneider-electric:smc_series_1018_ups_firmware, o:schneider-electric:smt_series_1015_ups_firmware, o:schneider-electric:smtl_series_1026_ups_firmware, o:schneider-electric:smx_series_1031_ups_firmwarenday's type rule vendor:schneider-electric
etapa
DIS
divulgación
cvss
sin puntuación aún

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2022-03-09T19:30Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Original text of the CVE record (cvelist), shown as published.

Registro de eventos

+DISdivulgación

schneider publicó el registro CVE.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 260673,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2022-22805",
  "occurred_at": "2022-03-09T19:30:16Z",
  "observed_at": "2026-11-13T05:37:37.656355Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2022-03-09T19:30:16.000Z",
    "assigner_short_name": "schneider"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.