nday
CVE-2021-47705

CNC_Ctrl DllUnregisterServer Access Violation

COMMAX Co., Ltd. / COMMAX UMS Client ActiveX Control

Apareció una PoC pública 1565 días antes de que se publicara el registro CVE. nday aún no tiene constancia de una corrección; eso no significa que no exista parche. La recoge 1 de las 4 fuentes de PoC: exploitdb. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

buffer overflow / out-of-bounds write
CWE-787, stated by the CNA VulnCheck y NVD, republishing [email protected]
network
AV:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA VulnCheck
no authentication required
PR:N in CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N (CVSS 4.0) from the CNA VulnCheck
Exploit-DB
Exploit-DB entries 50232
etapa
POC
divulgación
cvss
8.7 HIGH v4.0

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2025-12-09T20:37Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
2021-08-27, solo fecha
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

COMMAX UMS Client ActiveX Control 1.7.0.2 contains a heap-based buffer overflow vulnerability that allows attackers to execute arbitrary code by providing excessively long string arrays through multiple functions. Attackers can exploit improper boundary validation in CNC_Ctrl.dll to cause heap corruption and potentially gain system-level access.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:N
Network: the attacker only needs to reach it over the network
Attack complexity AC:L
Low: no target-specific security measures to get around
Attack requirements AT:N
None: success does not depend on how the target is deployed or running
Privileges required PR:N
None: no account or authorization needed
User interaction UI:P
Passive: limited, involuntary interaction, such as visiting a page

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

CVSS 4.0 vector from the CVE record, scored by the CNA VulnCheck.

Registro de eventos

2021-08-27solo fecha, según la fuente
+POCPoC pública

Exploit-DB recoge el exploit público «COMMAX UMS Client ActiveX Control 1.7.0.2 - 'CNC_Ctrl.dll' Heap Buffer Overflow» (EDB-50232).

fuente exploitdb 50232 · nday , observado en tiempo real · en bruto
{
  "id": 501396,
  "type": "poc_published",
  "source": "exploitdb",
  "url": "https://www.exploit-db.com/exploits/50232",
  "occurred_at": "2021-08-27T00:00:00Z",
  "observed_at": "2026-11-23T14:02:02.56302Z",
  "is_backfill": false,
  "dedupe_key": "50232",
  "detail": {
    "url": "https://www.exploit-db.com/exploits/50232",
    "file": "exploits/hardware/webapps/50232.txt",
    "kind": "exploit",
    "tags": [],
    "type": "webapps",
    "title": "COMMAX UMS Client ActiveX Control 1.7.0.2 - 'CNC_Ctrl.dll' Heap Buffer Overflow",
    "author": "LiquidWorm",
    "edb_id": 50232,
    "cve_ids": [
      "CVE-2021-47705"
    ],
    "platform": "hardware",
    "verified": false,
    "precision": "day",
    "confidence": "curated",
    "date_added": "2021-08-27",
    "date_updated": "2026-11-23",
    "date_published": "2021-08-27"
  }
}
+DISdivulgación

VulnCheck publicó el registro CVE. CVSS 8.7, severidad alta.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 253467,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2021-47705",
  "occurred_at": "2025-12-09T20:37:31.265Z",
  "observed_at": "2026-11-13T05:37:31.591644Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
      "version": "4.0",
      "base_score": 8.7,
      "base_severity": "HIGH"
    },
    "ssvc": {
      "timestamp": "2025-12-09T21:35:07.779372Z",
      "automatable": "no",
      "exploitation": "none",
      "technical_impact": "partial"
    },
    "state": "PUBLISHED",
    "date_published": "2025-12-09T20:37:31.265Z",
    "assigner_short_name": "VulnCheck"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.