CVE-2019-10964

Medtronic MiniMed 508 and Paradigm Series Insulin Pumps Improper Access Control

Medtronic / MiniMed 508 pump, MiniMed Paradigm 511 pump, MiniMed Paradigm 512/712 pumps, MiniMed Paradigm 712E pump, MiniMed Paradigm 515/715 pumps, MiniMed Paradigm 522/722 pumps +5

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

authentication bypass
CWE-287, stated by NVD's analysts
broken access control
CWE-284, stated by the CNA icscert y NVD, republishing [email protected]CWE-863, stated by NVD's analysts
adjacent network
AV:A in CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H (CVSS 3.1) from the CNA icscert
no authentication required
PR:N in CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H (CVSS 3.1) from the CNA icscert
no user interaction
UI:N in CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H (CVSS 3.1) from the CNA icscert
etapa
DIS
divulgación
cvss
7.1 HIGH v3.1

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2019-06-28T20:58Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

Medtronic MiniMed Insulin Pumps

are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

Original text of the CVE record (cvelist), shown as published.

Exploit conditions

What an attack needs, read from the CVSS vector.
Attack vector AV:A
Adjacent: only from a nearby network, such as the same LAN segment or Bluetooth range
Attack complexity AC:H
High: success depends on conditions outside the attacker's control, such as gathering details of the target or winning a race
Privileges required PR:N
None: no account or authorization needed
User interaction UI:N
None: no action by anyone other than the attacker

CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H

CVSS 3.1 vector from the CVE record, scored by the CNA icscert.

Registro de eventos

+DISdivulgación

icscert publicó el registro CVE. CVSS 7.1, severidad alta.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 202503,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2019-10964",
  "occurred_at": "2019-06-28T20:58:07Z",
  "observed_at": "2026-11-13T05:36:55.820159Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "cvss": {
      "source": "cna",
      "vector": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:H/A:H",
      "version": "3.1",
      "base_score": 7.1,
      "base_severity": "HIGH"
    },
    "state": "PUBLISHED",
    "date_published": "2019-06-28T20:58:07.000Z",
    "assigner_short_name": "icscert"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.