nday
CVE-2018-4844

Siemens SIMATIC: broken access controlTítulo compuesto por nday; el registro CVE no tiene título.

Siemens AG / SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOS

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

broken access control
CWE-284, stated by the CNA siemens y NVD, republishing [email protected]
improper privilege management
CWE-269, stated by NVD's analysts
adjacent network
AV:A in CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N (CVSS 3.1) from NVD's analysts
Siemens SIMATIC
affected products in the CVE record: Siemens AG · SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOSCPE names NVD's analysts give as vulnerable: a:siemens:simatic_wincc_oa_ui
ICS / OT
affected products in the CVE record: Siemens AG · SIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOSCPE names NVD's analysts give as vulnerable: a:siemens:simatic_wincc_oa_uithe product type of Siemens SIMATIC in nday's product registry
etapa
DIS
divulgación
cvss
sin puntuación aún

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2018-03-20T14:00Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Original text of the CVE record (cvelist), shown as published.

Registro de eventos

+DISdivulgación

siemens publicó el registro CVE.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 181510,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2018-4844",
  "occurred_at": "2018-03-20T14:00:00Z",
  "observed_at": "2026-11-13T05:36:42.797974Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2018-03-20T14:00:00.000Z",
    "assigner_short_name": "siemens"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.