nday
CVE-2018-10594

ICS-CERT Delta Industrial Automation COMMGR and…: buffer overflow / out-of-bounds writeTítulo compuesto por nday; el registro CVE no tiene título.

ICS-CERT / Delta Industrial Automation COMMGR and accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1)

Apareció una PoC pública 6 días después de la divulgación. nday aún no tiene constancia de una corrección; eso no significa que no exista parche. La recogen 2 de las 4 fuentes de PoC: exploitdb y metasploit. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

buffer overflow / out-of-bounds write
CWE-119, stated by NVD's analystsCWE-121, stated by the CNA icscert y NVD, republishing [email protected]
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.0) from NVD's analysts
network
AV:N in CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.0) from NVD's analysts
no authentication required
PR:N in CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.0) from NVD's analysts
no user interaction
UI:N in CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (CVSS 3.0) from NVD's analysts
Metasploit
Metasploit modules exploit/windows/scada/delta_ia_commgr_bof
Exploit-DB
Exploit-DB entries 44965, 45574
ICS / OT
CPE names NVD's analysts give as vulnerable: a:deltaww:commgrnday's type rule vendor:delta-electronics
etapa
POC
divulgación
divulgación → PoC
T+6d POC: solo fecha
cvss
sin puntuación aún

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2018-06-26T20:00Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
2018-07-02, solo fecha +1 más
metasploit
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.

Original text of the CVE record (cvelist), shown as published.

Registro de eventos

+DISdivulgación

icscert publicó el registro CVE.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 65714,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2018-10594",
  "occurred_at": "2018-06-26T20:00:00Z",
  "observed_at": "2026-11-12T23:01:25.305088Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2018-06-26T20:00:00.000Z",
    "assigner_short_name": "icscert"
  }
}
2018-07-02solo fecha, según la fuente
+POCPoC pública

Exploit-DB recoge el exploit público «Delta Industrial Automation COMMGR 1.08 - Stack Buffer Overflow (PoC)» (EDB-44965).

fuente exploitdb 44965 · nday , importación masiva · en bruto
{
  "id": 21337,
  "type": "poc_published",
  "source": "exploitdb",
  "url": "https://www.exploit-db.com/exploits/44965",
  "occurred_at": "2018-07-02T00:00:00Z",
  "observed_at": "2026-11-12T15:24:40.221206Z",
  "is_backfill": true,
  "dedupe_key": "44965",
  "detail": {
    "url": "https://www.exploit-db.com/exploits/44965",
    "file": "exploits/hardware/dos/44965.py",
    "kind": "exploit",
    "tags": [
      "Buffer Overflow"
    ],
    "type": "dos",
    "title": "Delta Industrial Automation COMMGR 1.08 - Stack Buffer Overflow (PoC)",
    "author": "t4rkd3vilz",
    "edb_id": 44965,
    "cve_ids": [
      "CVE-2018-10594"
    ],
    "platform": "hardware",
    "verified": false,
    "precision": "day",
    "confidence": "curated",
    "date_added": "2018-07-02",
    "date_updated": "2018-07-02",
    "date_published": "2018-07-02"
  }
}
2018-10-09solo fecha, según la fuente
+POCPoC pública

Exploit-DB recoge el exploit público «Delta Electronics Delta Industrial Automation COMMGR 1.08 - Stack Buffer Overflow (Metasploit)» (EDB-45574). Verificado por Exploit-DB.

fuente exploitdb 45574 · nday , importación masiva · en bruto
{
  "id": 46836,
  "type": "poc_published",
  "source": "exploitdb",
  "url": "https://www.exploit-db.com/exploits/45574",
  "occurred_at": "2018-10-09T00:00:00Z",
  "observed_at": "2026-11-12T15:24:40.221206Z",
  "is_backfill": true,
  "dedupe_key": "45574",
  "detail": {
    "url": "https://www.exploit-db.com/exploits/45574",
    "file": "exploits/windows/remote/45574.rb",
    "kind": "exploit",
    "tags": [
      "Metasploit Framework (MSF)",
      "Remote"
    ],
    "type": "remote",
    "title": "Delta Electronics Delta Industrial Automation COMMGR 1.08 - Stack Buffer Overflow (Metasploit)",
    "author": "Metasploit",
    "edb_id": 45574,
    "cve_ids": [
      "CVE-2018-10594"
    ],
    "platform": "windows",
    "verified": true,
    "precision": "day",
    "confidence": "curated",
    "date_added": "2018-10-09",
    "date_updated": "2018-10-09",
    "date_published": "2018-10-09"
  }
}
se desconocela fuente no indica fecha
+POCPoC pública

Metasploit incluye el módulo exploit/windows/scada/delta_ia_commgr_bof (Delta Electronics Delta Industrial Automation COMMGR 1.08 Stack Buffer Overflow). La fuente no indica cuándo se publicó el módulo.

fuente metasploit exploit/windows/scada/delta_ia_commgr_bof · nday , importación masiva · en bruto
{
  "id": 52955,
  "type": "poc_published",
  "source": "metasploit",
  "url": "https://github.com/rapid7/metasploit-framework/blob/master/modules/exploits/windows/scada/delta_ia_commgr_bof.rb",
  "occurred_at": null,
  "observed_at": "2026-11-12T15:24:51.477477Z",
  "is_backfill": true,
  "dedupe_key": "exploit/windows/scada/delta_ia_commgr_bof",
  "detail": {
    "url": "https://github.com/rapid7/metasploit-framework/blob/master/modules/exploits/windows/scada/delta_ia_commgr_bof.rb",
    "kind": "msf_module",
    "path": "/modules/exploits/windows/scada/delta_ia_commgr_bof.rb",
    "rank": 300,
    "check": false,
    "title": "Delta Electronics Delta Industrial Automation COMMGR 1.08 Stack Buffer Overflow",
    "cve_ids": [
      "CVE-2018-10594"
    ],
    "fullname": "exploit/windows/scada/delta_ia_commgr_bof",
    "rank_name": "normal",
    "confidence": "curated",
    "module_type": "exploit",
    "module_last_modified": "2025-06-23 12:43:46 +0000",
    "vuln_disclosure_date": "2018-07-02"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.