nday
CVE-2017-6780

A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could…Título compuesto por nday; el registro CVE no tiene título.

Fecha de divulgación: . nday aún no tiene constancia de una corrección; eso no significa que no exista parche. Ninguna de las cuatro fuentes de PoC la recoge. No figura en el KEV de CISA.

why these tags

nday derives these tags by fixed rules from the facts below; NVD, the CNA and other sources do not assign them. Vocabulary and rules: ~/tags.

resource exhaustion
CWE-770, stated by NVD's analysts
remote, unauthenticated
AV:N, PR:N, UI:N in CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.0) from NVD's analysts
network
AV:N in CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.0) from NVD's analysts
no authentication required
PR:N in CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.0) from NVD's analysts
no user interaction
UI:N in CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H (CVSS 3.0) from NVD's analysts
etapa
DIS
divulgación
cvss
sin puntuación aún

Ciclo de vida

Eje x en UTC; punto = minuto exacto, barra ancha = solo fecha, hueco = desconocida o inferida.
fecha desconocida
DISdivulgada
2017-09-07T21:00Z
PATparcheada
sin registro aún
ANAanalizada
sin registro aún
POCPoC
sin registro aún
ITWexplotada
sin registro aún
KEVen KEV
sin registro aún

Descripción

A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164.

Original text of the CVE record (cvelist), shown as published.

Registro de eventos

+DISdivulgación

cisco publicó el registro CVE.

fuente cvelist · nday , importación masiva · en bruto
{
  "id": 167375,
  "type": "disclosed",
  "source": "cvelist",
  "url": "https://www.cve.org/CVERecord?id=CVE-2017-6780",
  "occurred_at": "2017-09-07T21:00:00Z",
  "observed_at": "2026-11-13T05:36:33.334897Z",
  "is_backfill": true,
  "dedupe_key": "",
  "detail": {
    "state": "PUBLISHED",
    "date_published": "2017-09-07T21:00:00.000Z",
    "assigner_short_name": "cisco"
  }
}

Report an error

report an error or omission

Something on this page wrong or missing? Tell the editors; if they accept it, this page's revision log says so publicly. Upstream data is not changed.

Debate de investigadores

0 investigadores lo mencionaron en los últimos 7 días

Publicaciones en X de investigadores de la lista de nday que mencionan este CVE, tal como se publicaron. nday no las verifica.

nday aún no ha recopilado publicaciones en X de investigadores de su lista sobre este CVE.

Discussion

0 comments

No comments yet.